281.491.2331 13839 West Bellfort Street Sugar Land, TX
281.491.2331 13839 West Bellfort Street Sugar Land, TX
Certified
ISO 9001:2015
U.S. Patents
90 + U.S. Patents
Experts
Over 60 Years of Experience
Get A Quote

CRN

ProvinceProductDescriptionRegistration NumberDrawing Number
ACIC
New Brunswick
CP-2
CP-2G
CP-2GM
Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
1645 psig at 400 °F
0H08251.29087YTN
(avail. upon p.o.)
-
ACIC
Newfoundland & Labrador
CP-2
CP-2G
CP-2GM
Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
1645 psig at 400 °F
0H08251.29087YTN
(avail. upon p.o.)
-
ACIC
Northwest Territories
CP-2
CP-2G
CP-2GM
Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
1645 psig at 400 °F
0H08251.29087YTN
(avail. upon p.o.)
-
ACIC
Nova Scotia
CP-2
CP-2G
CP-2GM
Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
1645 psig at 400°F
0H08251.29087YTN
(avail. upon p.o.)
-
ACIC
Nunavut
CP-2
CP-2G
CP-2GM
Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
1645 psig at 400 °F
0H08251.29087YTN
(avail. upon p.o.)
-
ACIC
Prince Edward Island
CP-2
CP-2G
CP-2GM
Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
1645 psig at 400°F
0H08251.29087YTN
(avail. upon p.o.)
-
ACIC
Yukon
CP-2
CP-2G
CP-2GM
Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
1645 psig at 400°F
0H08251.29087YTN
(avail. upon p.o.)
-
ACIC
Nova Scotia
CP-2GMConstant Pressure Cylinder
1800 psig at -20 °F to 100 °F
3600 psig at -20°F to 100°F
0H12078.8AD071CACRN8
AD282BO.CRN8
ACIC
New Brunswick
CP-5Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H07394.27AD078CO.N.CRN
ACIC
Newfoundland & Labrador
CP-5Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H07394.20AD078CO.N.CRN
ACIC
Northwest Territories
CP-5Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H07394.2TAD078CO.N.CRN
ACIC
Nova Scotia
CP-5Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H07394.28AD078CO.N.CRN
(avail. upon request)
ACIC
Nunavut
CP-5Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H07394.2NAD078CO.N.CRN
ACIC
Prince Edward Island
CP-5Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H07394.29AD078CO.N.CRN
ACIC
Yukon
CP-5Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H07394.2YAD078CO.N.CRN
ACIC
New Brunswick
LSSM
GSSM
Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 100 °F
0F06939.27AD659COCRN
AD590CECRN
ACIC
Newfoundland & Labrador
LSSM
GSSM
Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 100 °F
0F06939.20AD659COCRN
AD590CECRN
ACIC
Northwest Territories
LSSM
GSSM
Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 100 °F
0F06939.2TAD659COCRN
AD590CECRN
ACIC
Nova Scotia
LSSM
GSSM
Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 100 °F
0F06939.28AD659COCRN
AD590CECRN
ACIC
Nunavut
LSSM
GSSM
Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 100 °F
0F06939.2NAD659COCRN
AD590CECRN
ACIC
Prince Edward Island
LSSM
GSSM
Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 100 °F
0F06939.29AD659COCRN
AD590CECRN
ACIC
Yukon
LSSM
GSSM
Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 100 °F
0F06939.2YAD659COCRN
AD590CECRN
ACIC
New Brunswick
CP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H2574.7AD159BKCRN8
ACIC
Newfoundland & Labrador
CP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H2574.70AD159BKCRN8
ACIC
Northwest Territories
CP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H2574.7TAD159BKCRN8
ACIC
Nova Scotia
CP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H2574.78AD159BKCRN8
ACIC
Nunavut
CP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H2574.7NAD159BKCRN8
ACIC
Prince Edward Island
CP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H2574.79AD159BKCRN8
ACIC
Yukon
CP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H2574.7YAD159BKCRN8
AlbertaAIDAutomatic Insertion Device
MAOP: 1480 psig at -20°F to 100 °F
MAOT: 500 °F at 1200 psig
0H13501.2AD809BT.CRN
AlbertaAPMAdjustable Probe Manual Insertion
240 psig at -20 °F to 100 °F
160 psig at 400 °F
0H13340.2AD778BXCRN
AlbertaBIP-1
BIP-2
BIP-3
Bellow Injection Pump
2160 psig at -20 °F to 100 °F
(BIP-1, BIP-2)
2000 psig at -20°F to 100°F(BIP-3)
EXEMPTAD788BO
AD788BB
AD788BC
AlbertaCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 100 °F
1645 psig at -20°F to 400°F
Materials of construction: 316/316L SS
0H08251.2AD066COCRN
AD040COCRN
AD068COCRN
AD071CACRN
AlbertaCP-2Constant Pressure Cylinder
Third design condition added.
1800 psig at -20 °F to 100 °F
1645 psig at -20 °F to 400 °F
1235 psig at -20°F to 450°F
0H08251.2AD071CACRN
AlbertaCP-2Constant Pressure Cylinder
MAOP: 1800 psig at -20 °F to 120 °F
MOAT: 500 °F @ 1634 psig
Process Temperature Range 50 °F to 500 °F
PendingAD071CACRN.5
AlbertaCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 100 °F
1645 psig at -20 °F to 400 °F
1235 psig at -20 °F to 450 °F
0H08251.2AD040COCRN.2
AlbertaCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 100 °F
Hastelloy C276
0H12708.2AD071CX.H.CRN
AlbertaCP-2HPConstant Pressure Cylinder
3600 psig at -20 °F to 100 °F
For non-corrosive service only.
0H10120.2AD065CO
AD141CA
AD141CF
AD141CL
AD141CO
AD141CO.O2
AD618BA
(avail. upon request)
AD618BA
(avail. upon request)
AD618BA.K
(avail. upon request)
AD618BA.O
(avail. upon request)
AlbertaCT-1Cooling Tower
6000 psig
PendingME2370OO[][]CRN
AlbertaCVK-CCheck Valve
3000 psig
PendingAD021ADCRN
AlbertaESRExternal Sand Relief
500 psig at -20 °F to 100 °F
This design is in accordance with the ASME B31.3 Code.
0H11878.2
(avail. upon p.o)
AD089BB.NCRN
AlbertaF-4BF-4B Filter Dryer
1500 psig -20 °F to 120 °F
0H16966.2AD440CACRN
AlbertaFTOFarm Tap Odorizer
3 Gallon
MAWP: 218 psig
Design Temperature: 302 °F
MDMT: -40 °F
V9059.2
(avail. upon p.o.)
AD730BPCRN.1
AlbertaFTOFarm Tap Odorizer
100 PSIG
W7455.2AD730BRCRN.1
AlbertaFT Spool740 psig at -20 °F to 100 °F
625 psig at -20 °F to 428 °F
The design is in accordance with the ASME B31.3 Code
0H11865.2FT2420NCRN
AlbertaFT Spool740 psig at -20 °F to 100 °F
625 psig at -20 °F to 428 °F
0H12534.2FT4420NCRN
AlbertaHeated Sample EnclosureThis design is in accordance with the ASME BPV Code Section VIII-1, 2010 edition. All S.S. 316/316L material shall be dual certified by the mill as
SA-240-316/316L.
740 psig at -20 °F to 450 °F
0H11487.2GS1524CRN
AlbertaInjection Probe with Check275 psig at -20 °F to 100 °F0H09839.2AD631DP.3
AlbertaIR-4SS3600 psig at -20 °F to 100 °FPendingAD015BOCRN
AlbertaIR-4SSHF3600 psig at -20 °F to 100 °FPendingAD015BJCRN
AlbertaIR-4SSInstrument Regulator
3600 psig at -20 °F to 100 °F
0H15075.2AD015BOCRN
AD017A[]CRN
AlbertaIRA-4SSAutomatic Insertion Instrument Regulator
MAOP: 2160 psig -20 °F to 120 °F
0H15197.2AD172DFCRN
AlbertaIRA-6KPAutomatic Insertion Instrument Regulator
MAOP: 2160 psig -20 °F to 120 °F
0H15197.2AD172FTCRN
AlbertaIRA-4SSFAutomatic Insertion Instrument Regulators
MAOP: See Table 6 on Drawings
-20 °F to 100 °F
0H15196.2AD172CNCRN
AD172CKCRN
AD172CICRN
AlbertaIRDProbe Regulator
MAOP: 3600 psig at -20 °F to 100 °F
MAOT: 450 °F at 1910 psig
0H13517.2AD171CO.K.CRN
AlbertaLE-2SSLiquid Eliminator
MAOP: 1440 PSIG @ -20 °F to 100 °F
AD691BO.CRN
AlbertaLE-2SSKO-FProbe Mounted Liquid Eliminator
600 psig at -20 °F to 100 °F
227 psig at -20 °F to 428 °F
0H11152.2AD691BY.CRN
AlbertaLS-14Liquid Sampling System
MAOP 2160 psig -20 °F to 120 °F
PendingAD245.HCRN
AlbertaLSM-6FCrude Oil Sampler
MOC: 316/316 SS, Carbon Steel, 2507 Duplex, or 2205 Duplex
Seals: Viton, Kalrez 4079, Kalrez 0040, Buna Nitrile, or Nuna Nitrile 4067
2" MNPT 150, 300 and 600 ANSI
Temperature Range: -50 °F to 600 °F
0H16716.2AD087CO.OCRN
AlbertaLSM-6FAICrude Oil Sampler
150, 300 and 600 ANSI, 450 °F.
Temperature Range: -50 °F to 600 °F
0H16718.2AD083CXCRN
AlbertaLSM-12FTDACrude Oil Sampler
2220 psig at -20 °F to 100 °F
1871 psig at -20 °F to 428 °F
100 psig at -20 °F to 428 °F
The design is in accordance with the ASME B31.3 Code.
0H11891.2AD221CZ.NCRN
AlbertaLSM-12FTDACrude Oil Sampler
2220 psig at -20 °F to 100 °F
1871 psig at -20 °F to 428 °F
100 psig at -20 °F to 428 °F
0H11891.2AD221CZ.NCRN.1
AlbertaManifold BlockManafold Block
3000 psig at -50 °F to 600 °F
0H16969.2MB1058CRN
MB1059CRN
AlbertaNV-2Needle Valve
MAOP at -20 °F to 392 °F.
0C15633.2NV2000
NV2MF
AlbertaNV-1Needle Valve
6000 psig
PendingAD456AGCRN
AlbertaPP-2Pitot Probe
MOC: 316 / 316L SS
3600 psig at -20 °F to 200 °F
3600 psig at >200 °F to 500 °F
1000 psig at >500 °F to 600 °F
0H16739.2AD626COCRN
AlbertaPP-2Pitot Probe
3600 psig at 100 °F
3000 psig at 200 °F
ASME B31.1, 2007 edition.
0H11506.2AD626BPCRN
AlbertaPP-2Pitot Probe
3600 psig at -20 °F to 100 °F
625 psig at -20 °F to 428 °F
0H11506.2AD626BPCRN.1
AlbertaPP-2Pitot Probe
3600 psig at -20 °F to 100 °F
625 psig at -20 °F to 428 °F
0H11506.2AD626BPCRN.2
AlbertaSG-3Sight Glass
2000 psig at -20 °F to 100 °F
PendingAD037LMCRN
AlbertaSG-4Sight Glass
2000 psig at -20 °F to 100 °F
PendingAD037LNCRN
AlbertaSP-1Both Welker and SAMI Instruments designs
SP-1 and SP-2
(based on body MNPT size):
-20 °F to 392 °F.
-AD631BC.1CRN
AD631BC.1CRN.1
AD631IH.CRN
AD631II.CRN
AlbertaSP-1Sample Probe
MAOP at -20 °F to 392 °F.
0H10001.2AD631IH.CRN
AD631II.CRN
AlbertaSP-2Sample Probe
MAOP at -20 °F to 392 °F.
0H10001.2AD631BC.1CRN
AD631BC.1CRN.1
AlbertaSP-2Sample Probe
3600 psig at -20 °F to 120 °F
ASME SA 479 grade 316 SS (base), ASME SA 213 grade 316 SS (tubing).
0H10001.2AD631BC.1CRN
AlbertaSP-2½" 6000 psig
¾ " 6,000 psig
1" 5,129 psig
-50 °F to 120 °F
ASME Sectopm VIII, DIV 1, 2013 Edition
0H16358.2AD631BC.1CRN.1
AD631BC.1CRN
AlbertaSSO-91800 psig at -20 °F to 120 °FPendingAD243DGCRN
AlbertaSSO-9M2160 psig at -20 °F to 120 °FPendingAD243DICRN
British ColumbiaCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 100 °F
1645 psig at -20 °F to 400 °F
0H08251.21AD066COCRN
AD040COCRN
AD068COCRN
AD071CACRN
British ColumbiaCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 140 °F
PendingAD066COCRN.1
British ColumbiaLSSM-1HPLiquid Sampler with Vanishing Chamber
3600 psig at -20 °F to 120 °F
PendingAD546BC.1CRN1
British ColumbiaSP-2Sample Probe
10" insertion
3600 psig at -20 °F to 120 °F
0H1267.31AD631GDCRN.1
ManitobaCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H08251.24
(avail. upon p.o.)
-
OntarioCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H08251.25
(avail. upon p.o.)
-
OntarioCP-2GMConstant Pressure Cylinder
300 psig at -20 °F to 100 °F
0H14623.5AD071CACRN5.1
OntarioCP-2GMContstant Pressure Cylinder
1800 psig at -20 °F to 100 °F
0H15236.5AD071CACRN5.2
OntarioCP-2GMConstant Pressure Cylinder
1800 psig at -20 °F to 100 °F
0H15236.5ADD1AD071CACRN5.2
OntarioCP-2HPConstant Pressure Cylinder
3600 psig at -20 °F to 100 °F
0H14771.5AD141CO.O2.CRN5
OntarioCP-30Validation Cylinder
6.6 Gallon
300 psig at -20 °F to 120 °F
0H16619.5AD159BMCRN5
OntarioCP-78GPMCConstant Pressure Validation Tank
40 Gallon
MAOP: 300 psig at -20 °F to 120 °F. Design Pressure: 375 psig at -20 °F to 120 °F.
M8449.5AD852BB.CRN5
OntarioFTOFarm Tap Odorizer
5 Gallon
300 psig at -20 °F to 100 °F
EXEMPTAD730BH.5CRN
OntarioLSM-6Liquid Sampler
MAOP PROCESS: See Table #1 on drawing.
MAOT: 300 °F
MDMT: -50 °F
0H17826.5AD087CO.OCRN5
OntarioLSSM-1Liquid Sampler with Vanishing Chamber
3600 psig at -20 °F to 120 °F
EXEMPTAD659COCRN5
OntarioLS-7PMEConstant Pressure Sample Cylinder
1300 psig at -20 °F to 120°F
100 psig at -20°F to 120 °F
0H14659.5AD191BPCRN5
OntarioRVP SkidRefined Product Sampling System
MAOP:300 psig at -20 °F to 120 °F
Design Pressure: 375 psig at -20 °F to 120 °F
Skid includes CP-2GM, LS-7PME,
SSO-9M, fittings and other CRN buyouts
0H14705.5LS3121CRN5
OntarioNV-2Needle Valve
6000 psig at -20 °F to 392 °F.
0C15633.25NV2000
NV2MF
OntarioSP-1
SP-2
Both Welker and SAMI Instruments designs
SP-1 and SP-2
(based on body MNPT size):
-20 °F to 392 °F
NV-2 MAOP:
6000 psig at -20 °F to 392 °F. Description on website: Sample Probe
MAOP at -20 °F to 392 °F.
0H10001.25AD631BC.1CRN
AD631BC.1CRN.1
AD631IH.CRN
AD631II.CRN
OntarioSSO-9MMini Injection Pump
1440 psig at -20 °F to 100 °F
0H14647.5AD640BO.CRN5
OntarioPP-2FPitot Probe
1440 psig at -20 °F to 100 °F
0H15235.5AD843BFCRN5
OntarioPP-2FPitot Probe
1440 psig at -20 °F to 100 °F
0H15235.5ADD1PP1193CRN5
QuebecCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H08251.26
(avail. upon p.o.)
-
SaskatchewanCP-2Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
0H08251.23
(avail. upon p.o.)
-
SaskatchewanSP-2Sample Probe
10" insertion
3600 psig at -20 °F to 120 °F
0H1267.3AD631GDCRN.3