Province | Product | Description | Registration Number | Drawing Number |
---|---|---|---|---|
ACIC New Brunswick | CP-2 CP-2G CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F 1645 psig at 400 °F | 0H08251.29087YTN (avail. upon p.o.) | - |
ACIC Newfoundland & Labrador | CP-2 CP-2G CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F 1645 psig at 400 °F | 0H08251.29087YTN (avail. upon p.o.) | - |
ACIC Northwest Territories | CP-2 CP-2G CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F 1645 psig at 400 °F | 0H08251.29087YTN (avail. upon p.o.) | - |
ACIC Nova Scotia | CP-2 CP-2G CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F 1645 psig at 400°F | 0H08251.29087YTN (avail. upon p.o.) | - |
ACIC Nunavut | CP-2 CP-2G CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F 1645 psig at 400 °F | 0H08251.29087YTN (avail. upon p.o.) | - |
ACIC Prince Edward Island | CP-2 CP-2G CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F 1645 psig at 400°F | 0H08251.29087YTN (avail. upon p.o.) | - |
ACIC Yukon | CP-2 CP-2G CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F 1645 psig at 400°F | 0H08251.29087YTN (avail. upon p.o.) | - |
ACIC Nova Scotia | CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 100 °F 3600 psig at -20°F to 100°F | 0H12078.8 | AD071CACRN8 AD282BO.CRN8 |
ACIC New Brunswick | CP-5 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H07394.27 | AD078CO.N.CRN |
ACIC Newfoundland & Labrador | CP-5 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H07394.20 | AD078CO.N.CRN |
ACIC Northwest Territories | CP-5 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H07394.2T | AD078CO.N.CRN |
ACIC Nova Scotia | CP-5 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H07394.28 | AD078CO.N.CRN (avail. upon request) |
ACIC Nunavut | CP-5 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H07394.2N | AD078CO.N.CRN |
ACIC Prince Edward Island | CP-5 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H07394.29 | AD078CO.N.CRN |
ACIC Yukon | CP-5 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H07394.2Y | AD078CO.N.CRN |
ACIC New Brunswick | LSSM GSSM | Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 100 °F | 0F06939.27 | AD659COCRN AD590CECRN |
ACIC Newfoundland & Labrador | LSSM GSSM | Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 100 °F | 0F06939.20 | AD659COCRN AD590CECRN |
ACIC Northwest Territories | LSSM GSSM | Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 100 °F | 0F06939.2T | AD659COCRN AD590CECRN |
ACIC Nova Scotia | LSSM GSSM | Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 100 °F | 0F06939.28 | AD659COCRN AD590CECRN |
ACIC Nunavut | LSSM GSSM | Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 100 °F | 0F06939.2N | AD659COCRN AD590CECRN |
ACIC Prince Edward Island | LSSM GSSM | Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 100 °F | 0F06939.29 | AD659COCRN AD590CECRN |
ACIC Yukon | LSSM GSSM | Liquid Sampler with Vanishing Chamber & Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 100 °F | 0F06939.2Y | AD659COCRN AD590CECRN |
ACIC New Brunswick | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H2574.7 | AD159BKCRN8 |
ACIC Newfoundland & Labrador | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H2574.70 | AD159BKCRN8 |
ACIC Northwest Territories | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H2574.7T | AD159BKCRN8 |
ACIC Nova Scotia | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H2574.78 | AD159BKCRN8 |
ACIC Nunavut | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H2574.7N | AD159BKCRN8 |
ACIC Prince Edward Island | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H2574.79 | AD159BKCRN8 |
ACIC Yukon | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H2574.7Y | AD159BKCRN8 |
Alberta | AID | Automatic Insertion Device MAOP: 1480 psig at -20°F to 100 °F MAOT: 500 °F at 1200 psig | 0H13501.2 | AD809BT.CRN |
Alberta | APM | Adjustable Probe Manual Insertion 240 psig at -20 °F to 100 °F 160 psig at 400 °F | 0H13340.2 | AD778BXCRN |
Alberta | BIP-1 BIP-2 BIP-3 | Bellow Injection Pump 2160 psig at -20 °F to 100 °F (BIP-1, BIP-2) 2000 psig at -20°F to 100°F(BIP-3) | EXEMPT | AD788BO AD788BB AD788BC |
Alberta | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 100 °F 1645 psig at -20°F to 400°F Materials of construction: 316/316L SS | 0H08251.2 | AD066COCRN AD040COCRN AD068COCRN AD071CACRN |
Alberta | CP-2 | Constant Pressure Cylinder Third design condition added. 1800 psig at -20 °F to 100 °F 1645 psig at -20 °F to 400 °F 1235 psig at -20°F to 450°F | 0H08251.2 | AD071CACRN |
Alberta | CP-2 | Constant Pressure Cylinder MAOP: 1800 psig at -20 °F to 120 °F MOAT: 500 °F @ 1634 psig Process Temperature Range 50 °F to 500 °F | Pending | AD071CACRN.5 |
Alberta | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 100 °F 1645 psig at -20 °F to 400 °F 1235 psig at -20 °F to 450 °F | 0H08251.2 | AD040COCRN.2 |
Alberta | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 100 °F Hastelloy C276 | 0H12708.2 | AD071CX.H.CRN |
Alberta | CP-2HP | Constant Pressure Cylinder 3600 psig at -20 °F to 100 °F For non-corrosive service only. | 0H10120.2 | AD065CO AD141CA AD141CF AD141CL AD141CO AD141CO.O2 AD618BA (avail. upon request) AD618BA (avail. upon request) AD618BA.K (avail. upon request) AD618BA.O (avail. upon request) |
Alberta | CT-1 | Cooling Tower 6000 psig | Pending | ME2370OO[][]CRN |
Alberta | CVK-C | Check Valve 3000 psig | Pending | AD021ADCRN |
Alberta | ESR | External Sand Relief 500 psig at -20 °F to 100 °F This design is in accordance with the ASME B31.3 Code. | 0H11878.2 (avail. upon p.o) | AD089BB.NCRN |
Alberta | F-4B | F-4B Filter Dryer 1500 psig -20 °F to 120 °F | 0H16966.2 | AD440CACRN |
Alberta | FTO | Farm Tap Odorizer 3 Gallon MAWP: 218 psig Design Temperature: 302 °F MDMT: -40 °F | V9059.2 (avail. upon p.o.) | AD730BPCRN.1 |
Alberta | FTO | Farm Tap Odorizer 100 PSIG | W7455.2 | AD730BRCRN.1 |
Alberta | FT Spool | 740 psig at -20 °F to 100 °F 625 psig at -20 °F to 428 °F The design is in accordance with the ASME B31.3 Code | 0H11865.2 | FT2420NCRN |
Alberta | FT Spool | 740 psig at -20 °F to 100 °F 625 psig at -20 °F to 428 °F | 0H12534.2 | FT4420NCRN |
Alberta | Heated Sample Enclosure | This design is in accordance with the ASME BPV Code Section VIII-1, 2010 edition. All S.S. 316/316L material shall be dual certified by the mill as SA-240-316/316L. 740 psig at -20 °F to 450 °F | 0H11487.2 | GS1524CRN |
Alberta | Injection Probe with Check | 275 psig at -20 °F to 100 °F | 0H09839.2 | AD631DP.3 |
Alberta | IR-4SS | 3600 psig at -20 °F to 100 °F | Pending | AD015BOCRN |
Alberta | IR-4SSHF | 3600 psig at -20 °F to 100 °F | Pending | AD015BJCRN |
Alberta | IR-4SS | Instrument Regulator 3600 psig at -20 °F to 100 °F | 0H15075.2 | AD015BOCRN AD017A[]CRN |
Alberta | IRA-4SS | Automatic Insertion Instrument Regulator MAOP: 2160 psig -20 °F to 120 °F | 0H15197.2 | AD172DFCRN |
Alberta | IRA-6KP | Automatic Insertion Instrument Regulator MAOP: 2160 psig -20 °F to 120 °F | 0H15197.2 | AD172FTCRN |
Alberta | IRA-4SSF | Automatic Insertion Instrument Regulators MAOP: See Table 6 on Drawings -20 °F to 100 °F | 0H15196.2 | AD172CNCRN AD172CKCRN AD172CICRN |
Alberta | IRD | Probe Regulator MAOP: 3600 psig at -20 °F to 100 °F MAOT: 450 °F at 1910 psig | 0H13517.2 | AD171CO.K.CRN |
Alberta | LE-2SS | Liquid Eliminator MAOP: 1440 PSIG @ -20 °F to 100 °F | AD691BO.CRN | |
Alberta | LE-2SSKO-F | Probe Mounted Liquid Eliminator 600 psig at -20 °F to 100 °F 227 psig at -20 °F to 428 °F | 0H11152.2 | AD691BY.CRN |
Alberta | LS-14 | Liquid Sampling System MAOP 2160 psig -20 °F to 120 °F | Pending | AD245.HCRN |
Alberta | LSM-6F | Crude Oil Sampler MOC: 316/316 SS, Carbon Steel, 2507 Duplex, or 2205 Duplex Seals: Viton, Kalrez 4079, Kalrez 0040, Buna Nitrile, or Nuna Nitrile 4067 2" MNPT 150, 300 and 600 ANSI Temperature Range: -50 °F to 600 °F | 0H16716.2 | AD087CO.OCRN |
Alberta | LSM-6FAI | Crude Oil Sampler 150, 300 and 600 ANSI, 450 °F. Temperature Range: -50 °F to 600 °F | 0H16718.2 | AD083CXCRN |
Alberta | LSM-12FTDA | Crude Oil Sampler 2220 psig at -20 °F to 100 °F 1871 psig at -20 °F to 428 °F 100 psig at -20 °F to 428 °F The design is in accordance with the ASME B31.3 Code. | 0H11891.2 | AD221CZ.NCRN |
Alberta | LSM-12FTDA | Crude Oil Sampler 2220 psig at -20 °F to 100 °F 1871 psig at -20 °F to 428 °F 100 psig at -20 °F to 428 °F | 0H11891.2 | AD221CZ.NCRN.1 |
Alberta | Manifold Block | Manafold Block 3000 psig at -50 °F to 600 °F | 0H16969.2 | MB1058CRN MB1059CRN |
Alberta | NV-2 | Needle Valve MAOP at -20 °F to 392 °F. | 0C15633.2 | NV2000 NV2MF |
Alberta | NV-1 | Needle Valve 6000 psig | Pending | AD456AGCRN |
Alberta | PP-2 | Pitot Probe MOC: 316 / 316L SS 3600 psig at -20 °F to 200 °F 3600 psig at >200 °F to 500 °F 1000 psig at >500 °F to 600 °F | 0H16739.2 | AD626COCRN |
Alberta | PP-2 | Pitot Probe 3600 psig at 100 °F 3000 psig at 200 °F ASME B31.1, 2007 edition. | 0H11506.2 | AD626BPCRN |
Alberta | PP-2 | Pitot Probe 3600 psig at -20 °F to 100 °F 625 psig at -20 °F to 428 °F | 0H11506.2 | AD626BPCRN.1 |
Alberta | PP-2 | Pitot Probe 3600 psig at -20 °F to 100 °F 625 psig at -20 °F to 428 °F | 0H11506.2 | AD626BPCRN.2 |
Alberta | SG-3 | Sight Glass 2000 psig at -20 °F to 100 °F | Pending | AD037LMCRN |
Alberta | SG-4 | Sight Glass 2000 psig at -20 °F to 100 °F | Pending | AD037LNCRN |
Alberta | SP-1 | SP-1 and SP-2 (based on body MNPT size): -20 °F to 392 °F. | - | AD631BC.1CRN AD631BC.1CRN.1 AD631IH.CRN AD631II.CRN |
Alberta | SP-1 | Sample Probe MAOP at -20 °F to 392 °F. | 0H10001.2 | AD631IH.CRN AD631II.CRN |
Alberta | SP-2 | Sample Probe MAOP at -20 °F to 392 °F. | 0H10001.2 | AD631BC.1CRN AD631BC.1CRN.1 |
Alberta | SP-2 | Sample Probe 3600 psig at -20 °F to 120 °F ASME SA 479 grade 316 SS (base), ASME SA 213 grade 316 SS (tubing). | 0H10001.2 | AD631BC.1CRN |
Alberta | SP-2 | ½" 6000 psig ¾ " 6,000 psig 1" 5,129 psig -50 °F to 120 °F ASME Sectopm VIII, DIV 1, 2013 Edition | 0H16358.2 | AD631BC.1CRN.1 AD631BC.1CRN |
Alberta | SSO-9 | 1800 psig at -20 °F to 120 °F | Pending | AD243DGCRN |
Alberta | SSO-9M | 2160 psig at -20 °F to 120 °F | Pending | AD243DICRN |
British Columbia | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 100 °F 1645 psig at -20 °F to 400 °F | 0H08251.21 | AD066COCRN AD040COCRN AD068COCRN AD071CACRN |
British Columbia | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 140 °F | Pending | AD066COCRN.1 |
British Columbia | LSSM-1HP | Liquid Sampler with Vanishing Chamber 3600 psig at -20 °F to 120 °F | Pending | AD546BC.1CRN1 |
British Columbia | SP-2 | Sample Probe 10" insertion 3600 psig at -20 °F to 120 °F | 0H1267.31 | AD631GDCRN.1 |
Manitoba | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H08251.24 (avail. upon p.o.) | - |
Ontario | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H08251.25 (avail. upon p.o.) | - |
Ontario | CP-2GM | Constant Pressure Cylinder 300 psig at -20 °F to 100 °F | 0H14623.5 | AD071CACRN5.1 |
Ontario | CP-2GM | Contstant Pressure Cylinder 1800 psig at -20 °F to 100 °F | 0H15236.5 | AD071CACRN5.2 |
Ontario | CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 100 °F | 0H15236.5ADD1 | AD071CACRN5.2 |
Ontario | CP-2HP | Constant Pressure Cylinder 3600 psig at -20 °F to 100 °F | 0H14771.5 | AD141CO.O2.CRN5 |
Ontario | CP-30 | Validation Cylinder 6.6 Gallon 300 psig at -20 °F to 120 °F | 0H16619.5 | AD159BMCRN5 |
Ontario | CP-78GPMC | Constant Pressure Validation Tank 40 Gallon MAOP: 300 psig at -20 °F to 120 °F. Design Pressure: 375 psig at -20 °F to 120 °F. | M8449.5 | AD852BB.CRN5 |
Ontario | FTO | Farm Tap Odorizer 5 Gallon 300 psig at -20 °F to 100 °F | EXEMPT | AD730BH.5CRN |
Ontario | LSM-6 | Liquid Sampler MAOP PROCESS: See Table #1 on drawing. MAOT: 300 °F MDMT: -50 °F | 0H17826.5 | AD087CO.OCRN5 |
Ontario | LSSM-1 | Liquid Sampler with Vanishing Chamber 3600 psig at -20 °F to 120 °F | EXEMPT | AD659COCRN5 |
Ontario | LS-7PME | Constant Pressure Sample Cylinder 1300 psig at -20 °F to 120°F 100 psig at -20°F to 120 °F | 0H14659.5 | AD191BPCRN5 |
Ontario | RVP Skid | Refined Product Sampling System MAOP:300 psig at -20 °F to 120 °F Design Pressure: 375 psig at -20 °F to 120 °F Skid includes CP-2GM, LS-7PME, SSO-9M, fittings and other CRN buyouts | 0H14705.5 | LS3121CRN5 |
Ontario | NV-2 | Needle Valve 6000 psig at -20 °F to 392 °F. | 0C15633.25 | NV2000 NV2MF |
Ontario | SP-1 SP-2 | Both Welker and SAMI Instruments designs SP-1 and SP-2 (based on body MNPT size): -20 °F to 392 °F NV-2 MAOP: 6000 psig at -20 °F to 392 °F. Description on website: Sample Probe MAOP at -20 °F to 392 °F. | 0H10001.25 | AD631BC.1CRN AD631BC.1CRN.1 AD631IH.CRN AD631II.CRN |
Ontario | SSO-9M | Mini Injection Pump 1440 psig at -20 °F to 100 °F | 0H14647.5 | AD640BO.CRN5 |
Ontario | PP-2F | Pitot Probe 1440 psig at -20 °F to 100 °F | 0H15235.5 | AD843BFCRN5 |
Ontario | PP-2F | Pitot Probe 1440 psig at -20 °F to 100 °F | 0H15235.5ADD1 | PP1193CRN5 |
Quebec | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H08251.26 (avail. upon p.o.) | - |
Saskatchewan | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | 0H08251.23 (avail. upon p.o.) | - |
Saskatchewan | SP-2 | Sample Probe 10" insertion 3600 psig at -20 °F to 120 °F | 0H1267.3 | AD631GDCRN.3 |