Our Locations

Certifications · Compliance · Canada

Canadian Registration Numbers

Welker pressure-containing products are registered under Canadian provincial and territorial boiler and pressure vessel safety codes. Search by CRN, model, or description, or filter by province.

68

Active Registrations

7

Provincial Listings

Instant Search

Need Help?
Sales & Product Inquiries 281.491.2331
Field & Factory Service 281.207.1887
CRN Documentation sales@welker.com
Province

Registration No.ProductDescription & RatingsProvince
0H17082.27CP-2GMConstant Pressure Cylinder
1800 psig at -20 °F to 120 °F MAOT: 500 °F at 1634 psig Design Process Temp Range: -50 °F to 500 °F Design Ambient Temp Range: -40 °F to 140 °F MDMT: -50 °F
ACIC / NB
0H17046.2CT-1Cooling Tower
MAOP: 6000 psig MAOT: 600 °F @ 4000 psig MDMT: -50 °F
ACIC / NB
0H17410.2AIP-1Automatic Insertion Probe
MAOP: 2160 psig @ -65 °F to 100 °F MAOT: 450 °F MDMT: -65 °F
Alberta
0H17505.2AIP-1FAutomatic Insertion Probe
MAOP: Determined by Flange Rating MAOT: 450 °F MDMT: -65 °F
Alberta
0H17411.2AIP-2Automatic Insertion Probe
MAOP: 2160 psig @ -65 °F to 100 °F MAOT: 450 °F MDMT: -65 °F
Alberta
0H17506.2AIP-2FAutomatic Insertion Probe
MAOP: Determined by Flange Rating MAOT: 450 °F MDMT: -65 °F
Alberta
0H17082.2CP-2GMConstant Pressure Cylinder
MAOP: 1800 psig at -20 °F to 120 °F MAOT: 500 °F at 1634 psig Design Process Temp Range: -50 °F to 500 °F Design Ambient Temp Range: -40 °F to 140 °F MDMT: -50 °F
Alberta
0H17363.2CP-2HPConstant Pressure Cylinder
MAOP: 3600 psig at -20 °F to 120 °F MAOT: 450 °F @ 3600 psig Design Process Temp: -50 °F to 450 °F Design Ambient Temp: -40 °F to 140 °F MDMT: -50 °F
Alberta
0H18832.2CP-5MConstant Pressure Sample Cylinder
MAOP: 2160 psig @ -20 °F to 100 °F
Alberta
0H17046.2CT-1Cooling Tower
MAOP: 6000 psig MAOT: 600 °F @ 4000 psig MDMT: -50 °F
Alberta
0C17043.2CVK-CCheck Valve Assembly w/ Kepner
MAOP: 3000 psig MAOT: 600 °F MDMT: -50 °F
Alberta
0H17339.2ESR-1 & ESR-1KExternal Sand Relief & External Sand Relief with Kalrez Poppet/Seals
1500 psig at -20 °F to 120 °F
Alberta
0H16966.2F-4BFilter Dryer
MAOP: 1500 psig @ -20 °F to 120 °F Design Temp Range: -50 °F to 420 °F
Alberta
0H19482.2SPFFlanged Sample Probe
MAOP: 285 psig @ -20 °F to 120 °F
Alberta
0H17048.2LS-14Liquid Sampling System CPLS-14 Hydraulic Actuated
MAOP Process: 2160 psig MAOP Actuation: 125 psig MAOT Process: 500 °F MAOT Actuation: 200 °F MDMT: -50 °F Design Ambient Temp Range: -40 °F to 140 °F
Alberta
0H17048.21LS-14Liquid Sampling System CPLS-14 Hydraulic Actuated
MAOP Process: 2160 psig MAOP Actuation: 125 psig MAOT Process: 500 °F MAOT Actuation: 200 °F MDMT: -50 °F Design Ambient Temp Range: -40 °F to 140 °F
Alberta
0H16716.2LSM-6FCrude Oil Sampler LSM-6F DAAlberta
0H20442.2LSM-10inFlow™ ACE Crude Oil Sampler
MAOP per Flange rating @ -50 °F to 120 °F MAOT: 450 °F MDMT: -50 °F
Alberta
0H18931.2LSM-12FTCrude Oil Sampler
MAOP: 1480 psig @ -20 °F to 100 °F MAOT: 1310 psig @ 300 °F MDMT: -50 °F Hydrostatic Test: 2220 psig
Alberta
0H18931.2LSM-12FT & 12FTDAinFlow™ Crude Oil Sampler
2220 psig @ -20 °F to 120 °F MAOP Actuation: 50 psig MAOT: 500 °F MDMT: -50 °F
Alberta
0H16969.2MBManifold Block
MAOP: 3000 psig @ -50 °F to 600 °F
Alberta
0C21314.2NV-1Needle Valve
MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F
Alberta
0C17042.2NV-2 Valve KitNeedle Valve Kit
MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F
Alberta
0H17054.2SSO-9Adjustable Sample Pump w/ Check Valves, No Oil Pot
MAOP Process: 1800 psig @ -20 °F to 120 °F MAOP Actuation: 225 psig @ -20 °F to 120 °F Design Process Temp Range: -50 °F to 500 °F Design Actuation Temp Range: -40 °F to 400 °F
Alberta
0H17040.2SSO-9MEDInjection Pump, Pitot .25-7.5 cc
MAOP Process (for flange): Depends on Flange Rating MAOP Process (for NPT): 2160 psig MAOP Actuation: 150 psig MAOT Process: 500 °F MAOT Actuation: 400 °F MDMT: -50 °F
Alberta
0H19922.2TCC2.5 Gallon and 5 Gallon Tank options
MAOP: 136 psig @ -20 °F to 300 °F MDMT: -50 °F Hydro Test Pressure: 177 psig
Alberta
0H17274.2inLoop & GSSM-1HP SamplerinLoop & GSSM-1HP Sampler
MAOP: 3600 psig @ -20 °F to 120 °F MAOT: 400 °F MDMT: -50 °F
Alberta
0H17274.2inLoop (LSSM-1HP) & GSSM-1HPLiquid/Gas Sampler with Vanishing Chamber
3600 psig at -20 °F to 120 °F
Alberta
0H22602.2inLoop ACE Crude Oil SamplerinLoop ACE Crude Oil Sampler
MAOP: 1440 psig @ -20 °F to 120 °F MAOT: 400 °F MDMT: -50 °F
Alberta
0H7286.1Condensate Sampling SystemCondensate Sampling SystemB.C.
0H17082.21CP-2Constant Pressure Sample Cylinder
MAOP: 1800 psig @ -50 °F to 140 °F MAOT: 450 °F @ 1653 psig
B.C.
0F6461.1CP-2Constant Pressure Sample Cylinder
1800 psig @ -20 °F to 140 °F
B.C.
0H17082.21CP-2GMConstant Pressure CylinderB.C.
0E7264.1F-4 F-5 F-5LMAOP: 1500 psig @ -20 °F to 200 °F MAOT: 200 °F MDMT: -65 °FB.C.
0H7256.1GSS-1Vanishing Chamber Sampler
MAOP: 2160 psig @ -20 °F to 120 °F MAOT: 400 °F (Product) Hydro Test Pressure: 3240 psig MIN Diaphragm Housing Pressure: 65 psig MAX Diaphragm Housing Pressure: 100 psig
B.C.
0A7538.1IHRD-4SSMAOP: 2160 psig @ -20 °F to 120 °F MAOT: 200 °F MDMT: -50 °FB.C.
0H15197.21IRA-4SSAutomatic Insertion Instrument Regulator
MAOP: 2160 psig MDMT: -50 °F MAOT: 450 °F
B.C.
0H15196.21IRA-4SSFAutomatic Insertion Instrument Regulator
MAOP: Dependent on size of flange rating MAOT: 450 °F @ Pressure due to size of flange rating MDMT: -50 °F
B.C.
0H6456.1LSSM-1HPLight Liquid SamplerB.C.
0C21314.21NV-1Needle Valve
MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F
B.C.
0C25079.21RV-110Relief ValveB.C.
0H7108.1SP-1 SP-2Sample Probe
MAOP @ -50 °F to 300 °F Based on body MNPT size
B.C.
0H7849.1SP-FSample Probe
MAOP @ -20 °F to 100 °F Design Temperature: -285 °F to 158 °F
B.C.
0H17274.21inLoop & GSSM-1HP SamplerinLoop & GSSM-1HP Sampler
MAOP: 3600 psig @ -20 °F to 120 °F MAOT: 400 °F MDMT: -50 °F
B.C.
0H17082.27CP-2Constant Pressure Sample Cylinder
1800 psig @ -20 °F to 120 °F 1634 psig @ 500 °F MDMT: -50 °F
New Brunswick
0H17082.27CP-2GMConstant Pressure CylinderNew Brunswick
0C21314.27NV-1Needle Valve
MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F
New Brunswick
0H17082.25CP-2GMConstant Pressure Sample Cylinder
MAOP: 1800 psig @ -50 °F to 140 °F MAOT: 450 °F @ 1653 psig
Ontario
0H19873.5CP-5Constant Pressure Sample Cylinder, Gravity Mixer (GM) 5 Gallon
2160 psig at -20 °F to 100 °F
Ontario
0C17043.25CVK-CCheck Valve Assembly w/ Kepner
MAOP: 3000 psig MAOT: 600 °F
Ontario
0H20882.5IR-4SS / IR-4SSHFInstrument Regulator
MAOP: 3600 psig MAOT: 400 °F
Ontario
0H20911.5LS-14PMLight Liquid Sampling System
MAOP Process: 2160 psig MAOP Actuation: 125 psig MAOT Process: 400 °F MAOT Actuation: 200 °F MDMT: -50 °F
Ontario
0H22602.25LSM-10inLoop ACE Cell Sampler
MAWP Actuation: 200 psig MDMT: -50 °F
Ontario
0C21314.25NV-1Needle Valve
MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F
Ontario
0C20877.5RV-1DRelief Valve
MAOP: 3600 psig MAOT: 600 °F MDMT: -65 °F
Ontario
0H7108.15SP-1 SP-2Sample Probe
MAOP @ -50 °F to 300 °F Based on body MNPT size
Ontario
0H17040.25SSO-9MEDInjection Pump, Pitot .25-7.5 cc
MAOP Process (for NPT): 2160 psig MAOP Actuation: 225 psig
Ontario
0H23838.5TCC Optimum2.5 US Gallon Transportable Crude Container
MAOP: 136 psig @ -20 °F to 300 °F MDMT: -50 °F Hydro Test Pressure: 177 psig
Ontario
0H17082.26CP-2Constant Pressure Cylinder
1800 psig at -20 °F to 200 °F
Quebec
0H05085.6CP-5Constant Pressure Cylinder
2160 psig at -20 °F to 100 °F
Quebec
0H15075.26IR-4SS & IR-4SSHFInstrument Regulator
MAOP: 3600 psig MAOT: 600 °F MDMT: -50 °F (e.g. Part # IR04TOXBSQ)
Quebec
0C21314.26NV-1Needle Valve
MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F
Quebec
0H15075.26RV-1DRelief Valve
MAOP: 3600 psig MAOT: 600 °F MDMT: -65 °F
Quebec
0G05082.6RV-2CPAdjustable Relief
3600 psig @ -20 °F to 120 °F
Quebec
0H07108.6SP-1 & SP-2Sample Probe
MAOP @ -50 °F to 300 °F Based on body MNPT size
Quebec
0H17082.23CP-2GMConstant Pressure Cylinder
1800 psig @ -50 °F to 140 °F
Saskatchewan
0C21314.23NV-1Needle Valve
MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F
Saskatchewan
0H7108.13SP-1 SP-2Sample Probe
MAOP @ -50 °F to 300 °F Based on body MNPT size
Saskatchewan
No registrations match “”

Try a CRN (0H17082), a model (CP-2GM), or a keyword (needle valve), or set the province to All. Still can’t find it? Call 281.491.2331 or email sales@welker.com.

Tip: dashes and spaces are optional — “cp2gm” finds CP-2GM. Press / to jump to search. All listed registrations are active.

Understanding CRN

What Is a Canadian Registration Number?

A CRN is a registration number issued by a Canadian province or territory after its safety authority reviews and accepts the design of a boiler, pressure vessel, or pressure-retaining fitting. Pressure equipment needs a CRN in each province or territory where it will be installed and operated.

Design Reviewed

The design, materials, and pressure and temperature ratings are reviewed against the CSA B51 Boiler, Pressure Vessel, and Pressure Piping Code.

Registered Province by Province

Each province and territory has its own safety authority, so a CRN applies only in the jurisdictions where the design has been registered or accepted.

Required Before Installation

Inspectors and operators check for a valid CRN before pressure equipment goes into service. Having it on file keeps project approvals moving.

Reading the Number

How to Read a CRN

Everything before the decimal identifies the registered design. The digits after the decimal show where it's registered: the first digit is the province that first registered it, and each digit after that is a province that has also accepted it.

Example · CP-2GM in Ontario

0H17082.25

0H17082 — the registered Welker design

2 — first registered in Alberta

5 — also accepted in Ontario

Province Codes on This Page

British Columbia

1

Alberta

2

Saskatchewan

3

Ontario

5

Quebec

6

New Brunswick

7

Example: 0H17082.27 means the design was registered in Alberta (2) and accepted in New Brunswick (7).

Certifications & Compliance

Questions About Canadian Compliance?

Our team can provide CRN documentation, answer compliance questions, or help verify that Welker equipment meets your Canadian project requirements.

We use cookies