| 0H17082.27 | CP-2GM | Constant Pressure Cylinder 1800 psig at -20 °F to 120 °F MAOT: 500 °F at 1634 psig Design Process Temp Range: -50 °F to 500 °F Design Ambient Temp Range: -40 °F to 140 °F MDMT: -50 °F | ACIC / NB |
| 0H17046.2 | CT-1 | Cooling Tower MAOP: 6000 psig MAOT: 600 °F @ 4000 psig MDMT: -50 °F | ACIC / NB |
| 0H17410.2 | AIP-1 | Automatic Insertion Probe MAOP: 2160 psig @ -65 °F to 100 °F MAOT: 450 °F MDMT: -65 °F | Alberta |
| 0H17505.2 | AIP-1F | Automatic Insertion Probe MAOP: Determined by Flange Rating MAOT: 450 °F MDMT: -65 °F | Alberta |
| 0H17411.2 | AIP-2 | Automatic Insertion Probe MAOP: 2160 psig @ -65 °F to 100 °F MAOT: 450 °F MDMT: -65 °F | Alberta |
| 0H17506.2 | AIP-2F | Automatic Insertion Probe MAOP: Determined by Flange Rating MAOT: 450 °F MDMT: -65 °F | Alberta |
| 0H17082.2 | CP-2GM | Constant Pressure Cylinder MAOP: 1800 psig at -20 °F to 120 °F MAOT: 500 °F at 1634 psig Design Process Temp Range: -50 °F to 500 °F Design Ambient Temp Range: -40 °F to 140 °F MDMT: -50 °F | Alberta |
| 0H17363.2 | CP-2HP | Constant Pressure Cylinder MAOP: 3600 psig at -20 °F to 120 °F MAOT: 450 °F @ 3600 psig Design Process Temp: -50 °F to 450 °F Design Ambient Temp: -40 °F to 140 °F MDMT: -50 °F | Alberta |
| 0H18832.2 | CP-5M | Constant Pressure Sample Cylinder MAOP: 2160 psig @ -20 °F to 100 °F | Alberta |
| 0H17046.2 | CT-1 | Cooling Tower MAOP: 6000 psig MAOT: 600 °F @ 4000 psig MDMT: -50 °F | Alberta |
| 0C17043.2 | CVK-C | Check Valve Assembly w/ Kepner MAOP: 3000 psig MAOT: 600 °F MDMT: -50 °F | Alberta |
| 0H17339.2 | ESR-1 & ESR-1K | External Sand Relief & External Sand Relief with Kalrez Poppet/Seals 1500 psig at -20 °F to 120 °F | Alberta |
| 0H16966.2 | F-4B | Filter Dryer MAOP: 1500 psig @ -20 °F to 120 °F Design Temp Range: -50 °F to 420 °F | Alberta |
| 0H19482.2 | SPF | Flanged Sample Probe MAOP: 285 psig @ -20 °F to 120 °F | Alberta |
| 0H17048.2 | LS-14 | Liquid Sampling System CPLS-14 Hydraulic Actuated MAOP Process: 2160 psig MAOP Actuation: 125 psig MAOT Process: 500 °F MAOT Actuation: 200 °F MDMT: -50 °F Design Ambient Temp Range: -40 °F to 140 °F | Alberta |
| 0H17048.21 | LS-14 | Liquid Sampling System CPLS-14 Hydraulic Actuated MAOP Process: 2160 psig MAOP Actuation: 125 psig MAOT Process: 500 °F MAOT Actuation: 200 °F MDMT: -50 °F Design Ambient Temp Range: -40 °F to 140 °F | Alberta |
| 0H16716.2 | LSM-6F | Crude Oil Sampler LSM-6F DA | Alberta |
| 0H20442.2 | LSM-10 | inFlow™ ACE Crude Oil Sampler MAOP per Flange rating @ -50 °F to 120 °F MAOT: 450 °F MDMT: -50 °F | Alberta |
| 0H18931.2 | LSM-12FT | Crude Oil Sampler MAOP: 1480 psig @ -20 °F to 100 °F MAOT: 1310 psig @ 300 °F MDMT: -50 °F Hydrostatic Test: 2220 psig | Alberta |
| 0H18931.2 | LSM-12FT & 12FTDA | inFlow™ Crude Oil Sampler 2220 psig @ -20 °F to 120 °F MAOP Actuation: 50 psig MAOT: 500 °F MDMT: -50 °F | Alberta |
| 0H16969.2 | MB | Manifold Block MAOP: 3000 psig @ -50 °F to 600 °F | Alberta |
| 0C21314.2 | NV-1 | Needle Valve MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F | Alberta |
| 0C17042.2 | NV-2 Valve Kit | Needle Valve Kit MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F | Alberta |
| 0H17054.2 | SSO-9 | Adjustable Sample Pump w/ Check Valves, No Oil Pot MAOP Process: 1800 psig @ -20 °F to 120 °F MAOP Actuation: 225 psig @ -20 °F to 120 °F Design Process Temp Range: -50 °F to 500 °F Design Actuation Temp Range: -40 °F to 400 °F | Alberta |
| 0H17040.2 | SSO-9MED | Injection Pump, Pitot .25-7.5 cc MAOP Process (for flange): Depends on Flange Rating MAOP Process (for NPT): 2160 psig MAOP Actuation: 150 psig MAOT Process: 500 °F MAOT Actuation: 400 °F MDMT: -50 °F | Alberta |
| 0H19922.2 | TCC | 2.5 Gallon and 5 Gallon Tank options MAOP: 136 psig @ -20 °F to 300 °F MDMT: -50 °F Hydro Test Pressure: 177 psig | Alberta |
| 0H17274.2 | inLoop & GSSM-1HP Sampler | inLoop & GSSM-1HP Sampler MAOP: 3600 psig @ -20 °F to 120 °F MAOT: 400 °F MDMT: -50 °F | Alberta |
| 0H17274.2 | inLoop (LSSM-1HP) & GSSM-1HP | Liquid/Gas Sampler with Vanishing Chamber 3600 psig at -20 °F to 120 °F | Alberta |
| 0H22602.2 | inLoop ACE Crude Oil Sampler | inLoop ACE Crude Oil Sampler MAOP: 1440 psig @ -20 °F to 120 °F MAOT: 400 °F MDMT: -50 °F | Alberta |
| 0H7286.1 | Condensate Sampling System | Condensate Sampling System | B.C. |
| 0H17082.21 | CP-2 | Constant Pressure Sample Cylinder MAOP: 1800 psig @ -50 °F to 140 °F MAOT: 450 °F @ 1653 psig | B.C. |
| 0F6461.1 | CP-2 | Constant Pressure Sample Cylinder 1800 psig @ -20 °F to 140 °F | B.C. |
| 0H17082.21 | CP-2GM | Constant Pressure Cylinder | B.C. |
| 0E7264.1 | F-4 F-5 F-5L | MAOP: 1500 psig @ -20 °F to 200 °F MAOT: 200 °F MDMT: -65 °F | B.C. |
| 0H7256.1 | GSS-1 | Vanishing Chamber Sampler MAOP: 2160 psig @ -20 °F to 120 °F MAOT: 400 °F (Product) Hydro Test Pressure: 3240 psig MIN Diaphragm Housing Pressure: 65 psig MAX Diaphragm Housing Pressure: 100 psig | B.C. |
| 0A7538.1 | IHRD-4SS | MAOP: 2160 psig @ -20 °F to 120 °F MAOT: 200 °F MDMT: -50 °F | B.C. |
| 0H15197.21 | IRA-4SS | Automatic Insertion Instrument Regulator MAOP: 2160 psig MDMT: -50 °F MAOT: 450 °F | B.C. |
| 0H15196.21 | IRA-4SSF | Automatic Insertion Instrument Regulator MAOP: Dependent on size of flange rating MAOT: 450 °F @ Pressure due to size of flange rating MDMT: -50 °F | B.C. |
| 0H6456.1 | LSSM-1HP | Light Liquid Sampler | B.C. |
| 0C21314.21 | NV-1 | Needle Valve MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F | B.C. |
| 0C25079.21 | RV-110 | Relief Valve | B.C. |
| 0H7108.1 | SP-1 SP-2 | Sample Probe MAOP @ -50 °F to 300 °F Based on body MNPT size | B.C. |
| 0H7849.1 | SP-F | Sample Probe MAOP @ -20 °F to 100 °F Design Temperature: -285 °F to 158 °F | B.C. |
| 0H17274.21 | inLoop & GSSM-1HP Sampler | inLoop & GSSM-1HP Sampler MAOP: 3600 psig @ -20 °F to 120 °F MAOT: 400 °F MDMT: -50 °F | B.C. |
| 0H17082.27 | CP-2 | Constant Pressure Sample Cylinder 1800 psig @ -20 °F to 120 °F 1634 psig @ 500 °F MDMT: -50 °F | New Brunswick |
| 0H17082.27 | CP-2GM | Constant Pressure Cylinder | New Brunswick |
| 0C21314.27 | NV-1 | Needle Valve MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F | New Brunswick |
| 0H17082.25 | CP-2GM | Constant Pressure Sample Cylinder MAOP: 1800 psig @ -50 °F to 140 °F MAOT: 450 °F @ 1653 psig | Ontario |
| 0H19873.5 | CP-5 | Constant Pressure Sample Cylinder, Gravity Mixer (GM) 5 Gallon 2160 psig at -20 °F to 100 °F | Ontario |
| 0C17043.25 | CVK-C | Check Valve Assembly w/ Kepner MAOP: 3000 psig MAOT: 600 °F | Ontario |
| 0H20882.5 | IR-4SS / IR-4SSHF | Instrument Regulator MAOP: 3600 psig MAOT: 400 °F | Ontario |
| 0H20911.5 | LS-14PM | Light Liquid Sampling System MAOP Process: 2160 psig MAOP Actuation: 125 psig MAOT Process: 400 °F MAOT Actuation: 200 °F MDMT: -50 °F | Ontario |
| 0H22602.25 | LSM-10 | inLoop ACE Cell Sampler MAWP Actuation: 200 psig MDMT: -50 °F | Ontario |
| 0C21314.25 | NV-1 | Needle Valve MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F | Ontario |
| 0C20877.5 | RV-1D | Relief Valve MAOP: 3600 psig MAOT: 600 °F MDMT: -65 °F | Ontario |
| 0H7108.15 | SP-1 SP-2 | Sample Probe MAOP @ -50 °F to 300 °F Based on body MNPT size | Ontario |
| 0H17040.25 | SSO-9MED | Injection Pump, Pitot .25-7.5 cc MAOP Process (for NPT): 2160 psig MAOP Actuation: 225 psig | Ontario |
| 0H23838.5 | TCC Optimum | 2.5 US Gallon Transportable Crude Container MAOP: 136 psig @ -20 °F to 300 °F MDMT: -50 °F Hydro Test Pressure: 177 psig | Ontario |
| 0H17082.26 | CP-2 | Constant Pressure Cylinder 1800 psig at -20 °F to 200 °F | Quebec |
| 0H05085.6 | CP-5 | Constant Pressure Cylinder 2160 psig at -20 °F to 100 °F | Quebec |
| 0H15075.26 | IR-4SS & IR-4SSHF | Instrument Regulator MAOP: 3600 psig MAOT: 600 °F MDMT: -50 °F (e.g. Part # IR04TOXBSQ) | Quebec |
| 0C21314.26 | NV-1 | Needle Valve MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F | Quebec |
| 0H15075.26 | RV-1D | Relief Valve MAOP: 3600 psig MAOT: 600 °F MDMT: -65 °F | Quebec |
| 0G05082.6 | RV-2CP | Adjustable Relief 3600 psig @ -20 °F to 120 °F | Quebec |
| 0H07108.6 | SP-1 & SP-2 | Sample Probe MAOP @ -50 °F to 300 °F Based on body MNPT size | Quebec |
| 0H17082.23 | CP-2GM | Constant Pressure Cylinder 1800 psig @ -50 °F to 140 °F | Saskatchewan |
| 0C21314.23 | NV-1 | Needle Valve MAOP: 6000 psig MAOT: 500 °F MDMT: -65 °F | Saskatchewan |
| 0H7108.13 | SP-1 SP-2 | Sample Probe MAOP @ -50 °F to 300 °F Based on body MNPT size | Saskatchewan |