Turnkey Crude Oil Automatic Sampling

Crude Oil Sampling Systems Built for Custody Transfer

Complete automatic sampling systems — samplers, containers, mixers, panels, and controls — designed, manufactured, assembled, and tested by Welker. Delivered in an enclosure, on a skid, or inside a building.

API 8.2

Automatic Sampling

ISO 3171

Pipeline Sampling

ASTM D4177

Standard Practice

ISO 9001:2015

Certified

ISO 3171 | API 8.2

Representative Samples. Reliable Results

Accurate BS&W and crude oil quality results start with a representative sample. Welker integrates sampling, mixing, and sample handling to help preserve sample integrity from pipeline to lab.

Isokinetic Sample Extraction

inFlow™ samplers collect representative samples from the conditioned pipeline stream.

Mixing Solutions Tailored for Your Application

Static, fast-loop, and WelMix™ solutions are selected for your flow rate, viscosity, and water content.

Sampling Containers for Every Crude

A range of sampling  containers, Including the TCC Optimum™ — the only crude oil container with DOT and Transport Canada approval — and constant-pressure options for live crude. 

Closed-Loop, Emission-Conscious Design

Fully closed-loop  sample handling protects operators and the environment while preserving sample integrity. 

Designed & Built in Sugar Land, TX

From initial application review to system engineering, fabrication, FAT, commissioning, and support, Welker brings the entire crude oil sampling system together under one roof.One integrated system.

One experienced team. Confidence from pipeline to lab.

Welker crude oil sampling system with power mixing pump, inFlow sampler, and sample receivers inside an analyzer building

Analyzer Building · Power Mixing & Multi-Receiver Sampling

Your Site. Your Package.

Enclosure, Skid, or Building

Every Welker crude oil sampling system is delivered turnkey — piped, wired, and tested before it ships — in the package that fits your footprint, climate, and operating model.

Stainless steel crude oil sampling enclosure with hydraulic power unit and two sample containers

Enclosure

Sampling Enclosure

A compact, self-contained cabinet that protects the sampler controls, receivers, and power unit at LACT units, meter stations, and remote pads.

Small footprint, fast installation

Stainless steel construction

Optional heating for cold climates

crude oil sampling skid with canopy, dual hydraulic units, and ten sample containers

Skid

Skid-Mounted Systems

A structural skid — with optional canopy — that carries multiple receivers, redundant power units, and integrated controls for terminals and pipeline stations.

Multi-receiver & redundant designs

Single lift, minimal field work

Canopy or open-frame options

Climate-controlled analyzer building housing a complete Welker crude oil sampling and mixing system

Building

Analyzer Building

A climate-controlled, walk-in building for fiscal metering points that integrates the sampling loop, power mixing, analyzers, and sample handling under one roof.

HVAC, lighting & gas detection

Analyzer & densitometer integration

Ideal for terminals & export facilities

How It Works

From Pipeline to Laboratory in Six Steps

An automatic sampling system per API MPMS 8.2 combines flow conditioning, extraction, control, collection, and sample handling. Welker manufactures every one of them.

01

Flow Conditioning

The pipeline stream is homogenized so water and sediment are evenly dispersed at the sample point — using static mixing, a fast loop, or power mixing.

WelMix™ · Static Mixing Spool

02

Isokinetic Extraction

A Welker sampler inserted into the center third of the line, or into a fast loop, removes precise sample grabs at line velocity.

inFlow™ · inFlow™ ACE · inLoop™ ACE · FLP

03

Flow-Proportional Control

The controller paces each grab to meter pulses so the composite represents the full batch, with optional data logging and receiver monitoring.

Plug & Purge™ Panel · Checkpoint™ Panel

04

Composite Collection

Grabs are delivered to a sample receiver sized for the batch — atmospheric for stabilized crude or constant pressure for live crude.

TCC Optimum™ · TCC · SCC · CP-2

05

Sample Mixing

Stratified composites are re-homogenized in a closed loop so the laboratory subsample matches the contents of the whole container.

SCC · MSTCC Laboratory Mixing Skid

06

Laboratory Analysis

The representative subsample is tested for BS&W, density, and quality — the results that settle custody transfer and allocation.

BS&W · Density · Quality

System Configurations

Three Proven Sampling Architectures

Welker engineers select the architecture based on line size, flow range, crude properties, and the measurement uncertainty your contract requires.

Inline Sampling System

0.118%

Typical measurement uncertainty

The sampler is mounted directly on a well-mixed main line. A simple, proven, low-cost solution.

Best for

LACT units, gathering, well-mixed lines

Key Equipment

inFlow™ / inFlow™ ACE, static mixer, receivers

Fast Loop Sampling System

0.035%

Typical measurement uncertainty

A continuous bypass loop keeps the sample live and turbulent, then returns excess crude downstream.

Best for

Mixed pipelines, high pressure, densitometer integration

Key Equipment

inLoop™ ACE, pump, purge valve, receivers

*Typical values; actual system uncertainty depends on pipeline conditions and is confirmed during Welker engineering review and proving.

Built from Welker Components

Every Part of the System. One Manufacturer.

Welker turnkey systems are built around our own crude oil samplers, containers, mixers, and panels — so performance, spare parts, and support come from a single source.

Remove precise sample increments from a flowing pipeline for collection in a composite sampling system.

All Samplers

System Configurator

Find Your Crude Oil Sampling System

Answer three questions and we'll point you to a starting configuration. Our engineers confirm every detail during design review.

1 · Application
2 · Line & Crude
3 · Site Package

1. What is the primary purpose of the sample?

2. What best describes your line and crude?

3. How should the system be packaged?

Recommended Starting Point

Sampler
Container
Mixing
Package

Field-Proven Projects

Crude Oil Sampling Systems We've Built

From single-point enclosures to complete analyzer buildings, every system is fabricated and tested at Welker before it ships.

Standards We Design To

API 8.2

API 8.3

ISO 3171

ASTM D4177

IP/EI 6.2

Why Welker

One Source for the Entire Sampling System

Many sampling systems are assembled from multiple vendors' components. Welker designs and manufactures the core equipment in-house — and stands behind the complete system.

ConsiderationWelker Turnkey SystemTypical Multi-Vendor Approach
Core EquipmentSamplers, containers, mixers, and panels all manufactured by WelkerComponents sourced from several manufacturers
Mixing OptionsStatic, fast loop, and WelMix™ power mixing — selected to the applicationOften limited to one mixing technology
Sample TransportTCC Optimum™ — DOT and Transport Canada approvedIntermediary transfer containers add handling uncertainty
PackagingEnclosure, skid, or building — built and tested under one roofPackaging subcontracted or sold separately
AccountabilityOne point of contact from engineering review through startup and sparesResponsibility split across vendors
ExperienceSampling equipment designed and built since 1954Varies by integrator

FAQ

Crude Oil Sampling Questions

What is a crude oil automatic sampling system?

An automatic sampling system extracts small, flow-proportional grabs from a flowing pipeline and collects them into a composite sample that represents the entire batch. Per API MPMS 8.2, it includes flow conditioning, an automatic sampler, a controller, a flow measuring device, a sample receiver, and sample handling and mixing.

Which standards do Welker crude oil sampling systems meet?

Welker designs systems to API MPMS Chapter 8.2, ISO 3171, ASTM D4177, and IP/EI 6.2 as specified, with sample mixing and handling aligned to API MPMS 8.3.

Inline, fast loop, or power mixing — how do I choose?

Inline systems suit well-mixed main lines. Fast loop systems keep a live, turbulent sample stream for mixed pipelines and analyzer integration. WelMix™ power mixing homogenizes the line at any flow rate and delivers the lowest measurement uncertainty for fiscal transfer points. Our engineers make the final recommendation after reviewing your process data.

Can the system be delivered in an enclosure, on a skid, or in a building?

Yes. Welker delivers turnkey systems in stainless enclosures, structural skids with optional canopies, and climate-controlled analyzer buildings — fully piped, wired, and tested before shipment.

What information do you need to size a system?

Pipeline size and orientation, flow and pressure ranges, crude properties (density, viscosity, water, H₂S), hazardous area classification, available utilities, receiver preferences, and the standard you must comply with. Our Crude Oil Sampling Worksheet captures everything in one place.